The Jabsco Par-Max 1 series pumps are available as automatic and manual demand pumps. The 710237 will automatically turn on when a fixture is opened and turn off when fixtures are closed. When starting up an automatic demand pump with a completely dry system allow time for the demand pump to fill the system. Open a faucet, allow air to vent and close faucet when water flow is steady. Faucet strainers and aerators should be cleaned regularly.Features:- Self-Priming
- Dry Running
- Automatic Operation 42630-2900
- Meets U.S.C.G. Electrical Requirements
Specifications:- Motor: Permanent Magnet, Thermally Protected, Intermittent Duty
- Pump: Two chamber opposed double diaphragm design; Self-priming up to 4 ft. suction lift; Pump able to run dry without damage, Intermittent duty.
- Port: Pump housing inlet and outlet are 3/8" hose barb.
- Height: 2.28 In. (58mm)
- Width: 3.5 in. (89mm)
- Length: 6.37 in. (162mm)
- Weight: 1.3lbs. (0.60 Kg)
- Volts: 12V DC
- Amp Draw 10 Psi (0.7 Bar): 1.9
- Fuse Required: 4A
- Flow: 1.1 Gal./Min. (4.3 L/Min)
- Pressure Switch psi: On - 22(1.5)/Off - 35(2.4)
|
|
|
|
|
|
|
|

|